InsuliserBeta
Concepts · Heat

The U-value

Add up every resistance between inside air and outside air, including the two surface films, and invert the total. That is the U-value:

U = 1 ÷ (Routside film + Rlayer 1 + Rlayer 2 + … + Rinside film) (W/m²K)

A lower U-value means a better-insulated wall. The steady heat flow through it is then simply:

heat flow = U × (temperature difference)

Worked example. Take 100 mm of brick (R = 0.125) and 100 mm of insulation (R = 4.55), plus the two surface films (0.04 + 0.13 = 0.17). The total is 0.125 + 4.55 + 0.17 ≈ 4.85 m²K/W, so U ≈ 0.21 W/m²K. With 20 °C inside and 0 °C outside, the wall leaks about 20 ÷ 4.85 ≈ 4.1 W through each square metre. Those round numbers are illustrative; the simulator uses each material's own data.

The U-value assumes steady state: that the temperatures on both sides have been constant for long enough that nothing inside the wall is still warming up or cooling down. The rest of this page, and most of this tool, is about what happens when they are not.