Reading the moisture charts
The verdict
Above each wall's chart is one of these results. They only describe how much water the wall holds and when. Whether that water does harm is judged separately, layer by layer, in the checks that follow: rot for timber and fibre layers, frost for masonry, the interface behind internal insulation, gypsum, and mould on the inner surface. This follows how hygrothermal results are normally assessed, under WTA 6-5 for internal insulation.
| Result | What it means |
|---|---|
| Stays dry | No layer holds liquid water at any point in the year: every layer stays below the moisture it would hold at 95% humidity. |
| Gets wet, then dries out | Liquid water collects in winter, with a peak amount, month and layer, and has gone again by the month named. Rain-exposed walls often start to rewet in the autumn, which is normal. This is generally acceptable if the materials can tolerate that much moisture for a few months. |
| Stays damp all year | Some water is still there even in the driest month, but no more than the year before: the wall has settled at a damp level. Common for rain-exposed masonry, and not a fault in itself. The checks below say whether the materials suffer from it. |
| Gets wetter year on year | Water is still there even in the driest month, and more than the year before, so it builds up. The danger is rot, frost damage and loss of insulation. |
Moisture moving through each wall
- Black line: the vapour pressure actually in the wall, from the outside value on the left to the inside value on the right, as a monthly average. Both ends are labelled with temperature and humidity.
- Blue dashed line: the saturation pressure, the most the air can hold at the temperature of each point.
- Red dot: liquid water held in that layer at the end of the month, in g/m².
- Hollow blue dot: condensation in an air cavity, assumed to drain away through the weep holes. It is labelled with the amount that month but is not added to the water held in the wall.
- Arrows along the bottom: the moisture flow through each layer, vapour and liquid together. The dashes move in the direction it travels. A thicker, darker arrow means more.
- Play button and slider: step through the year from October. All the charts glide between months.
Ground moisture up the wall
Shown below each wall's vapour chart when the ground at the base is wet. It is the wall seen from the side, from the ground up to 3 m, with the same layers across. Blue shows how full of water each layer is, on one scale for every wall, from clear when dry to solid when saturated. Each layer matches its simulated wetness at 1 m, and in the wet zone the shading follows the same taper the simulation uses, wettest at the base and drying out towards the damp front, the line labelled with its height. Where the front stays below 1 m, the wall above it shows its own wetness from rain and vapour. Dashed arrows show water wicking up from the ground while it is wet. Arrows out of the outer face and inward show where it dries out, labelled in millimetres of water a day, thicker for more. Inward drying goes into the room, or into the layer behind if that doesn't wick, such as insulation, where it is usually small. The dashed line at 1 m is the height the vapour chart and the other results are for, labelled with how saturated the wettest layer is there.
Moisture held in the wall
Total liquid water held at the end of each month, in the last simulated year. If it never comes back to zero, the wall is not drying out. Where the wall is still getting wetter, a dashed line shows year one for comparison.
Inner surface humidity
The relative humidity of the air touching the inside face, by month, against the 80% mould line.
Comparing walls
Each column has its own build-up, chosen from the same library as the Compare tab, and all share one climate and indoor setting. The yearly charts then overlay every wall in its own colour. Changing a setting reruns every wall in the background, which takes a moment ("Calculating…").