3. Heating

Each heated room needs a radiator or underfloor loop that gives out at least its heat loss, at the water temperature the system runs at. The lower that temperature, the bigger the heater each room needs, and the more efficient a heat pump or condensing boiler runs.

  • System & flow: the flow temperature at the design outside temperature, and the drop from flow to return. With weather compensation, the flow falls as the weather warms, down to the value you set at 15 °C outside. The room that needs the hottest water to keep up sets the flow for the whole system.
  • Emitters: each room's need against its heaters' output at that flow temperature. A room shown short won't reach its setpoint on the coldest day. Add radiators to rooms without one sizes a radiator for each empty room. Radiator outputs are typical catalogue figures. Underfloor output depends on pipe spacing and floor covering, and is limited by a 29 °C floor surface.
  • Zones & UFH: group rooms into radiator zones and underfloor manifolds, with their own heating hours if needed.
  • Pipework: the pipes from the heat source to each heater. It shows the water flow in each run, whether the pump can push it round, and whether a heat pump gets the minimum flow it needs. Lay out typical pipework gives a starting point.
  • System diagram: the pipework drawn as a flow-and-return schematic, with the valves and the modes that set them (heating, hot water, each zone, cooling). See 3b. Valves, modes and cooling.

The heat source itself (boiler or heat pump), its output and its efficiency are chosen at the top of System & flow. Choosing one sets its typical max flow temperature and flow − return drop (80 °C and 11 K for an old boiler, 70 °C and 20 K for a condensing boiler, 45 °C and 5 K for a heat pump), so the radiators are checked at the flow that source really runs at. Your energy prices are under Results, on Energy & cost.