5. Solving each step
Each two-hour step is solved implicitly, which stays stable however thin the slices are. Heat comes first, then moisture. The unknown for moisture is each slice's humidity. Because storage, µ and capillary flow all depend on that humidity, the tool guesses it, works out the flows, solves for the new humidities, and repeats until no slice changes by more than 0.0001 (usually two to five passes). The storage term is set up so that water is conserved exactly at every pass. If a step won't settle, typically at the start of a shower, it is split in half, and halved again if needed.