Reading the results

ResultWhat it means
U-valueSteady-state heat loss per square metre per degree. Lower is better insulated.
Decrement factorShare of the outside heat swing reaching the inner face. Lower damps more.
Decrement delayHours between the outside peak and the inner heat-flow peak.
Inner thermal massHeat the wall stores and gives back to the room over a day, kJ/m²K. Whole-wall mass is shown beneath.
Inner faceThe lowest and highest inner surface temperature over the day.
Net heat flow, 24 hHeat gained minus heat lost through the wall over the day. Positive means a net gain to the room.
Room air, peak delayFree-floating mode only: the room's own temperature range, and how far behind the outdoor peak it runs.

The wall diagram

Each slice of each layer is coloured by its temperature. The scale is anchored on the room temperature, so blue always means colder than the room, red always warmer, and cream about the same, whichever scenario you are looking at. Arrows show heat flow through each slice: pointing right means towards the room, and a thicker arrow means more heat. When the arrows are different on either side of a layer, that layer is storing or releasing heat.

The charts

  • Temperatures: air, sol-air, both wall faces and the room, over 24 hours.
  • Heat flow into the room: the simulation against the steady-state estimate.
  • Sunshine on this face: the solar radiation reaching the wall.
  • Heat map: temperature through the depth of the wall (vertical) against time (horizontal), so you can see the heat wave travel inwards.

Why the swings matter, not just the net

Two walls can have the same net heat flow over 24 hours and still behave very differently. If the heat flow into the room swings widely and the heating is controlled closely enough to follow it, the system has to ramp up and down quickly to hold the room steady, and it needs enough capacity to cover the peaks. If it doesn't follow, as with underfloor heating or a heat pump on a steady flow temperature, the room temperature swings instead. A wall with small swings avoids both: a gentle, steady output keeps the room steady.

Swings can also raise the energy used, not only the peak power. If the wall gives heat in the afternoon and loses it overnight, the net can be close to zero while the room still needs cooling at one time and heating at another. Heating and cooling can't cancel each other out, so you pay for both. Systems also tend to run less efficiently when working hard or cycling on and off. On the other hand, if the swings are small enough for the room to ride through without the system switching on, they cost nothing. This is why a low decrement factor and a suitable decrement delay are worth looking at alongside the U-value.