InsuliserBeta
How the models work · Wall heat model

4. Slicing the wall

Each layer is divided into thin slices (cells): thinner for masonry such as brick and concrete, which stores most of the heat, and thicker for light insulation, which stores little. A layer with conductivity above 0.4 W/mK gets a slice about every 15 mm, and anything else about every 40 mm, with a minimum of 2 and a maximum of 14 slices per layer. Dense, low-conductivity materials such as wood fibre board and hempcrete are the exception: heat soaks into them only a few centimetres over a day, so 40 mm slices are coarse for them, and the tool slightly overstates their damping (its decrement factor comes out about 0.01–0.015 too low). Each slice is described by two numbers:

  • A heat capacity, C = density × specific heat × slice thickness (J/m²K), the size of its bucket.
  • A conductance to each neighbour, the reciprocal of resistance. Heat travels from the middle of one slice to the middle of the next, so the resistance between the two is the sum of half of each slice's own resistance: G = 1 ÷ (dx1/2k1 + dx2/2k2).

The first slice connects to the outside through the outside film (Rse), and the last to the room through the inside film (Rsi). Air layers hold almost no heat and are given a fixed resistance whatever their width: 0.18 m²K/W for a plain cavity, 0.66 or 0.72 for one with one or two foil faces. Multifoils also use their declared fixed resistance. A ventilated gap, such as a tile batten void, also exchanges heat directly with the outdoor air at a fixed 5 W/m²K, so the layers outside it count for less. Each slice is assumed to be at a single temperature, and the heat flows between neighbours are one-dimensional: straight through the thickness of the wall.