3b. Valves, modes and cooling

The pipework says where the water can go. The valves say where it does go at any moment. Both are set on the System diagram, which draws every run as a flow pipe (on top) and a return pipe (below), from the heat source on the left to the emitters on the right.

Pick a control plan

Under Control plan, choose a plan and press Add. The planner finds where each valve has to go on your pipework, puts it there, and fills in the plan's modes. The plans are the usual UK layouts: Y plan, S plan, S plan plus (a valve per zone), W plan, Heat pump (a diverter, zone valves and radiator isolation for cooling) and Combi. They are explained in Control plans, zones and cooling.

A valve shuts everything beyond it. Where several runs leave the same tee and one valve has to shut them all, the plan puts in a short header for the valve to sit on, shown on the diagram with its name. Where the runs that need shutting leave a shared pipe at different tees, the same valve is drawn on each of them. On site that means one actuator per branch wired together, or re-piping so the branches leave from one place. Remove the plan and its headers go too.

Modes

A mode is one state of the system: whether the source sends hot water, chilled water or nothing, and where each valve sits. Pick a mode in the bar above the diagram, or a row in the Modes table, and the diagram shows it. Pipes carrying water are coloured, with dots moving out along the flow and back along the return. Their speed follows the water velocity in that run. Heating is red, water going only to the cylinder is amber, and chilled water is blue. Each return is a paler shade of its flow. Shut runs turn grey. Each run's label gives its flow and velocity in the mode shown. The pipe size is chosen for the run's busiest mode, which the label names after sized for when it is a different mode. Each valve is a bowtie, hollow when open and filled when shut, and its gate turns along the pipe as it opens. Play modes steps through them in turn. Animation is switched off if your system asks for reduced motion.

Every cell in the table can be changed: rename a mode, change its water, or set any valve's position. Add mode copies the one showing so you can make your own, for example a night setback that heats only the bedrooms. Once you change anything, the plan is marked as your own (custom). Applying a plan again asks before it replaces your changes.

Moving and adding valves

Drag a valve onto another run to move it. Or press pick runs next to a valve in the Valves list and click runs in the diagram to put it on them or take it off. A 3-port valve has two ports: A (the plans use it for hot water) and B (heating). Pick runs for each port separately. Add valve makes a new 2-port valve and starts picking its runs. A valve's kind can be a 2-port zone valve, a 3-port mid-position valve (it can feed both ports at once) or a 3-port diverter (one port or the other).

What the modes change

  • Pipe sizes. Each run is sized for its busiest mode, and the index circuit is the worst of any mode. With hot water priority the primary carries the larger of the heating and the cylinder reheat, not both. The cylinder coil's reheat (set under Control plan) defaults to the source's output when a plan is first added. Each run's label says which mode it was sized for.
  • The simulations. An emitter is heated only if some hot mode reaches it, and cooled only if it can cool and some chilled mode reaches it. Shut a zone off in every mode and its rooms go cold in the runs.
  • Checks. The diagram flags a mode with every circuit shut (the pump runs against closed valves), chilled water reaching a radiator, towel rail or the cylinder, a diverter asked for both ports, cooling from a boiler, emitters no mode heats, and a cylinder no mode reheats.

Cooling

A heat pump can run in reverse. Turn it on under System & flow → Cooling, with its cooling output and EER (both at 35 °C outside and 18 °C water), the temperature to cool rooms to, and the chilled flow and its rise. Fan coils (an emitter kind on Emitters, or on the plan from a radiator's side panel) and underfloor loops can cool. Radiators and towel rails cannot. In the Summer peak day and Typical year runs, rooms with a cooling emitter are held at the cooling setpoint during their occupied hours. While the cooling is holding a room there, its windows stay shut. Outside those hours, or when the cooling cannot keep up, the windows are opened as in any other room. The Passivhaus-type demo shows this: fan coils in the living room and the two big bedrooms, on 7/12 °C chilled water. It is zoned as fan coils and radiators, so in cooling the radiator zone valve is shut. The cooling's electricity and cost are shown on their own, beside the heating figures on Energy & cost and in the report.