InsuliserBeta
Concepts · Moisture

Vapour resistance: µ and sd

Materials resist the passage of vapour much as they resist heat. Each material has a vapour resistance factor, µ (pronounced "mu"), which says how many times harder the vapour finds it to get through the material than through still air of the same thickness. Still air is µ = 1. Typical values:

Materialµ
Mineral wool, sheep's wool, cellulose1–2
Wood fibre boardabout 3–5
Brick, lime plasterabout 10–16
Softwood timberabout 50
EPS, unfaced PIR foam boardabout 50–60
Foil-faced PIR boardeffectively infinite (the foil facings)
Hard, dense limestoneabout 200 (soft limestones are far lower)
Metal, glass, foil-faced productseffectively infinite

To compare layers of different thickness, multiply by the thickness to get the equivalent air thickness, sd, in metres. It is the thickness of still air that would resist vapour equally:

sd = µ × thickness (m)

100 mm of unfaced PIR (µ 60) is sd = 6 m: as much resistance as six metres of air. Most PIR boards sold in the UK are foil-faced, which makes them effectively vapour-tight. The tool has both: "PIR / PUR board, foil-faced" for those, and "PIR / PUR board, unfaced" for bare boards, which let far more vapour through. A foil-faced board's resistance only holds if its joints are taped; gaps and unsealed edges let vapour and moist air past it. 80 mm of wood fibre (µ about 5) is only sd = 0.4 m. Like R-values, sd values in layers add up. The material picker shows µ where the tool has a figure. Many materials list two values, a dry-cup one and a wet-cup one, because materials such as wood fibre and lime let vapour through more easily when damp.

Layers with no µ in the tool's data are treated as fully open (µ = 1) and flagged on the page.