Vapour resistance: µ and sd
Materials resist the passage of vapour much as they resist heat. Each material has a vapour resistance factor, µ (pronounced "mu"), which says how many times harder the vapour finds it to get through the material than through still air of the same thickness. Still air is µ = 1. Typical values:
| Material | µ |
|---|---|
| Mineral wool, sheep's wool, cellulose | 1–2 |
| Wood fibre board | about 3–5 |
| Brick, lime plaster | about 10–16 |
| Softwood timber | about 50 |
| EPS, unfaced PIR foam board | about 50–60 |
| Foil-faced PIR board | effectively infinite (the foil facings) |
| Hard, dense limestone | about 200 (soft limestones are far lower) |
| Metal, glass, foil-faced products | effectively infinite |
To compare layers of different thickness, multiply by the thickness to get the equivalent air thickness, sd, in metres. It is the thickness of still air that would resist vapour equally:
100 mm of unfaced PIR (µ 60) is sd = 6 m: as much resistance as six metres of air. Most PIR boards sold in the UK are foil-faced, which makes them effectively vapour-tight. The tool has both: "PIR / PUR board, foil-faced" for those, and "PIR / PUR board, unfaced" for bare boards, which let far more vapour through. A foil-faced board's resistance only holds if its joints are taped; gaps and unsealed edges let vapour and moist air past it. 80 mm of wood fibre (µ about 5) is only sd = 0.4 m. Like R-values, sd values in layers add up. The material picker shows µ where the tool has a figure. Many materials list two values, a dry-cup one and a wet-cup one, because materials such as wood fibre and lime let vapour through more easily when damp.
Layers with no µ in the tool's data are treated as fully open (µ = 1) and flagged on the page.