4. Capillary flow
Liquid water moves through a wicking material from wetter to drier. Künzel's approximation gives its liquid diffusivity from the water absorption coefficient A and the free saturation:
It rises a thousandfold from dry to saturated, so a nearly dry material barely wicks and a wet one wicks fast. This is the suction value, used while it rains. Between showers, when water redistributes rather than being drawn in, a tenth of it is used, as Künzel recommends. The flow is driven by the gradient of relative humidity:
Driving the flow by humidity, not by water content, is what lets it cross from one material to the next: water moves from brick into a lime render whenever the brick is at a higher humidity, even though the two hold very different amounts at that humidity. A layer with no capillary data, or A of zero, passes no liquid at all, so water can only leave it as vapour.