Old solid walls are rarely wetted only by indoor vapour. Rain soaks the outer face, and moisture can rise from the ground. You can set both on the tab.

Rain exposure
Sheltered (urban, trees), moderate, exposed (hill, coast, south-west face) or severe. It sets how much of the month's rain actually lands on the wall: 5%, 15%, 30% or 50%. The rain falls as showers, and the outer face takes up only what its own capillarity allows. The rest runs off. Open brick soaks up most of a shower, a cement render less, granite and foam boards almost nothing.
Ground moisture
Dry ground or a working DPC, wet in winter, or wet all year: liquid water is available at the base of the wall from November to March, or all year. A damp-proof course (DPC) that works stops it reaching the wall above, which the tool treats the same as dry ground. The wet options assume there is none, or that it has failed or is bridged, for instance by render, raised ground or a path running over it. This is what is often called rising damp, a term worth using carefully: damp low on a wall is frequently condensation, rain getting in, raised ground or paths bridging the base, a leak, or salts drawing moisture from the air, so rule those out first. It is drawn up by capillary flow into the run of wicking layers from the outside, such as brick and stone, up to the first layer that doesn't wick, such as insulation. How far it rises depends on how well those layers wick and how fast the wall can dry: a vapour-tight render or internal insulation slows the drying, so the damp rises higher. The tool reports that height, and its results are for the wall 1 m above the footing.

Once in the wall, that water spreads by wicking and leaves by evaporating, either outward through the face or inward towards the room. In sunshine a wet face warms, its vapour pressure rises, and in summer it can exceed the room's, so the arrows reverse and moisture is driven inwards. A vapour-open insulation lets damp masonry dry into the room. A vapour-tight one does not, so the inward flow through it is almost nothing.

On the chart, a blue strip marks rain taken up by the outer face that month, and with wet ground, a second chart below shows the wall from the side, with the moisture climbing it.