4. Results
Design day
Design day is the heat loss in steady conditions at the design outside temperature: for each face, U-value × area × temperature difference, plus ventilation. The total is what the heating has to deliver on the coldest day, and the figure a heat pump is sized from. It breaks the total down by room and into fabric and ventilation, and shows where the heat goes.
Test the house
Test the house runs the house hour by hour, with sun, heat stored in the walls, people and the heating schedule:
- Winter design day: the peak, with the heating schedule and setback, on a cold overcast day.
- Typical year: energy by month and day, and hours each room is too cold or too warm. Use smooth monthly weather, or a real year of hourly weather for your station.
- Summer peak day: overheating in bedrooms and lofts, on a clear hot day with no heating. As in CIBSE TM59, windows are opened while someone is home, once a room passes 22 °C and it is cooler outside. The air they let through is single-sided stack flow (BS 5925), taking a fifth of each window's area as the open gap, with no help from wind.
- Cold snap: five days with the heating off, to see how long rooms hold their heat.
Party walls lose heat to the neighbour's set temperature only on the design day. In the other runs next door is taken to be lived in like this house, so no net heat crosses (as SAP treats a filled party wall); the wall still stores heat.
"Too cold" counts hours when the heating is meant to be on and a room is more than 1 K under its setpoint. "Too warm" counts hours above 25 °C, or 26 °C in bedrooms. Occupancy & gains sets the heating times and the heat from people, cooking and appliances. Why heavy walls change these results is in Thermal mass.
Energy and cost
Energy & cost turns the heat needed into energy bought, cost and carbon for the heat source chosen under Heating: an old boiler, a condensing boiler, or an air or ground source heat pump. Condensing boilers are more efficient with cooler return water. Heat pump efficiency (COP) is worked out from the flow and outside temperatures, and you can match it to a real unit by entering points from its datasheet. The ? buttons explain where each default comes from. Prices start at the current Ofgem price cap, so put in your own tariff.
Checking against bills
Check against bills compares the model with what the house actually used. Import smart meter readings as CSV or type in monthly gas use, then Match the model to the bills to scale it. A fit is good when the monthly error (CV(RMSE)) is under 15% and the yearly total is within 5%, as ASHRAE Guideline 14 recommends. The energy signature plots heating power against outside temperature, which gives the house's real heat loss per degree. It needs at least three heating months.
Moisture and the report
Moisture & mould shows each room's mould risk from its humidity and coldest surface, with what to do about it, and checks for moisture building up inside each build-up. See Condensation. Report & export prints a heat loss report, exports a room table as CSV, and saves or opens a project file.