1. Building the year

The outdoor air temperature uses the same monthly means as the heat tab (4.5 °C in January to 17 °C in July, plus the city offset), and the outdoor relative humidity a table of typical UK values, from 89–90% in winter to about 74% in May and June. Both change smoothly through the year, interpolated between mid-months, rather than jumping on the first of the month. The outdoor vapour pressure is then:

pout = RHout × psat(Tout)

The saturation pressure uses the standard formula from ISO 13788, with a slightly different constant below freezing:

psat = 610.5 × exp( 17.269 T ÷ (237.3 + T) ) (T at or above 0 °C)

The sun warms the outer face between 6 am and 6 pm, peaking at midday. Its 24-hour average is a typical monthly figure, from about 0.3 K in December to 5.5 K in June and July. Rain falls as a six-hour shower every 60 hours, about twelve a month, sharing out that month's rain on the wall: a typical Midlands monthly total (about 50 to 80 mm), scaled for the city from 0.8 for London to 1.4 for Cardiff, times the exposure share. Of the rain reaching the wall, 70% is taken to stay on the face and the rest to splash off, the usual default in hygrothermal tools. During a shower there is no sun and the outdoor humidity is at least 95%.

The room's vapour pressure is the outdoor pressure plus what the household adds. The moisture setting is the peak vapour excess in the room air: 2, 4 or 6 g/m³ for low, typical and high. It is strongest in the coldest weather, when windows are shut, and falls steadily to zero as the outdoor temperature rises from 0 to 20 °C:

excess = peak × (20 − Tout) ÷ 20 (with Tout held between 0 and 20 °C)
pin = pout + excess × 461.5 × (Tin + 273.15)

The 461.5 J/kgK is the gas constant for water vapour. The room pressure can never exceed saturation at room temperature, so it is capped there.