The fraction of incoming solar radiation that a surface absorbs. Pale surfaces have low values, dark surfaces high.
Air changes per hour (ACH)
How many times per hour the room's air is replaced by outside air.
Conductivity (k, λ)
How readily a material conducts heat, in W/mK. Lower means a better insulator.
Decrement factor
The fraction of the outside daily heat swing that reaches the inner surface, after being damped by the wall.
Decrement delay
The delay, in hours, between a peak outside and the resulting peak of heat flow at the inner face. Also called time lag or time shift.
Diffuse radiation
Sunlight scattered by the sky and clouds, arriving from all directions, as opposed to the direct beam.
Free-floating
A room with no heating or cooling, whose temperature is whatever its surroundings make it.
Hygroscopic
Able to take up moisture from the air and release it again. Wood fibre, wool, timber, lime and clay are, and so are stone and brick to a degree.
Interstitial condensation
Condensation that forms inside a wall, at a boundary between layers, rather than on a surface.
Irradiance
The power of solar radiation arriving on a surface, in W/m².
Operative temperature
A measure of how warm a room feels, combining air temperature and the temperature of surrounding surfaces. Roughly their average.
Perimeter upstand
A strip of insulation standing on edge between a floor's screed and the wall, breaking the heat path round the floor insulation at the floor-to-wall junction.
Psi (Ψ), linear thermal transmittance
The extra heat lost per metre of a junction, such as where the floor meets the wall, per kelvin of temperature difference, in W/mK, over and above what the U-values on either side count.
R-value (thermal resistance)
How strongly a layer resists heat flow, in m²K/W. Thickness divided by conductivity. Higher means better insulated.
Relative humidity (RH)
How much water vapour the air holds, as a percentage of the most it could hold at its temperature.
Rising damp
A contested name for moisture drawn up from the ground into the base of a wall by capillary action. It is often blamed for damp with other causes, such as condensation, rain getting in, raised ground bridging the base, leaks or salts. The tool calls it ground moisture, and models it only when water is actually available at the base.
Saturation vapour pressure
The most water vapour the air can hold at a given temperature, in pascals. It rises steeply as the air warms.
sd (equivalent air thickness)
A layer's vapour resistance expressed as the thickness of still air, in metres, that would resist vapour equally: µ × thickness.
Sol-air temperature
A notional outdoor temperature that combines the air temperature with the effect of absorbed sunshine.
Specific heat capacity
The energy needed to warm one kilogram of a material by one kelvin, in J/kgK.
Steady state
A condition in which temperatures have stopped changing with time.
Thermal bridge
A part of the structure that conducts heat more easily than its surroundings, letting heat bypass insulation.
Thermal mass
The ability of a material to store heat. High-density materials such as brick and concrete have a lot.
U-value
The steady rate of heat flow through one square metre of a wall per kelvin of temperature difference, in W/m²K. The reciprocal of total resistance.
Vapour pressure
The pressure exerted by the water vapour in the air, in pascals. It measures how much vapour there actually is, and vapour moves from high to low.
Vapour resistance factor (µ)
How many times more a material resists the passage of water vapour than still air of the same thickness. Dry-cup and wet-cup values apply to dry and damp conditions.